Next: Examples Up: Parameters Prev: Parameters
INTERVAL
Because the housekeeping parameters follow the usual laws of
statistics it is common to have small chunks of "GOOD" data in a
large section of "BAD" data. e.g. if you are selecting Master veto
rate data between 0 and 170 only, then there may be a five minute
period where the Master veto rate is constantly above 170, but then
drops to 160 for a 2 second period before rising to above 170 for
another 5 minutes. Rather than include a large number of these
small and probably spurious "GOOD" time windows, a minimum length
of a time window is set by the program. The default is 10 seconds
but this may be overridden on the command line.

Next: Examples Up: Parameters Prev: Parameters